O mechanically coded cable prevents reverse polarity installation.
Asi bus flat cable.
The conductor is contacted by piercing technology within the asi modules.
Binary on off devices such as actuators sensors rotary encoders analog inputs and outputs push buttons and valve position sensors in discrete.
As interface actuator sensor interface asi is an industrial networking solution physical layer data access method and protocol used in plc dcs and pc based automation systems.
Flat cable splitters and insulation displacement connectors.
Shf1 can bus offshore marine approved bus cables dnv gl approved.
The conductor is contacted by piercing technology within the asi modules.
As i bus also known as actuator sensor interface is an industrial networking solution that is the alternative to hard wiring field devices.
Knx cable now available to cpr class cca s1a d1 a1.
Data and energy are transmitted between control unit and peripherals via an unscreened geometrically coded two core flat cable pole safe.
As i stands for actuator sensor interface and is one of the network protocols for automated solutions and the cable.
If you have any further questions you can.
Asi bus asi is standardized europe wide in en 50295 and internationally in iec 62026 2 network system for the lowest field level binary sensors and actuators.
It is designed for connecting simple field i o devices e g.
Fsc adds tree cable to bms cable range.
The as i bus cable is part of the veriflex cable portfolio designed with precision for control and fieldbus applications.
The yellow flat cable needs to be protected from uv radiation.
Steel wire armoured power cables.
As interface flat cable insulation displacement connector flat cable connector m12 optional info productavailability error dear customer unfortunately this data sheet is not available in the requested language.
O mechanically coded cable prevents reverse polarity installation.
Copper mans eternal metal.
Selecting the cable o note.
Tree cable designed for loxone system.
It is used to connect simple devices like actuators and sensors on and off switches push buttons and more in automation applications.
Data and power are transmitted via an unscreened geometrically coded two core flat cable protection against polarity reversal.
The sensors are connected to the asi modules coupling modules using round cables connection cables.
Fs cables and cablecraft make a connection to form cca group.
Data and power are transmitted via an unscreened geometrically coded two core flat cable protection against polarity reversal.
The as i cable is unusual shape trapezoidal with a lip with the conductors in a flat configuration.
The conductor is contacted by piercing technology within the asi modules.
O for currents 2a the voltage drop along the cable must be checked.
O piercing technology allows simple and fast installation without tools.
The sensors are connected to the asi modules coupling modules using round cables connection cables.
O for currents 2a the voltage drop along the cable must be checked.